QSourceAI includes an optional Gaze Tester for people who want to rehearse their on-camera setup before a video interview. The feature is different from a continuous live gaze alert: it is a short calibration exercise in the Windows application. After you permit camera access, it uses a local face-and-iris landmark model to compare the direction of your eyes with two references you choose. The result can help you explore how the position of the webcam and answer reader affects your gaze. It does not certify eye contact, attention, honesty, or professional performance. This guide explains the actual steps and the limitations that matter.
What Gaze Tester does in the Windows application
The purpose of Gaze Tester is to help you experiment with a comfortable reading position. In a video meeting, you may be looking at another person's face or reading notes below the physical webcam. The direction can appear different on the other side of the call. QSourceAI's tester gives you an approximate reference from your own setup: a sample when you look into the camera lens and a sample when you look toward text near the top of the app. It then checks a short rehearsal against those calibrated directions. It is not an always-on monitoring or attention-rating service. It is an optional tool you start intentionally.
Step 1: Start the local camera preview
Open the QSourceAI desktop app and navigate to Settings → Gaze tester → Start camera preview. The feature checks for its tracking component; it may install a verified local model file if needed. Windows and Electron may request permission to use your webcam. Give permission only if you want to run the exercise. Position yourself in reasonably even lighting, with your face in view and only one person in the camera frame. The feature analyzes face and iris landmarks on your device rather than sending video frames to the QSourceAI AI-response service. The camera preview continues until you stop it or leave the view.
Step 2: Calibrate the webcam-lens reference
Select 1 · Calibrate lens, then look directly at the physical webcam lens while the app collects usable reference samples. Keep your head reasonably steady during this brief calibration. The tool uses multiple landmark observations rather than judging a single glance. If it cannot collect enough consistent samples, it asks you to try again. Improve lighting, reduce reflections from glasses, and avoid moving out of frame. This reference represents the approximate iris direction associated with looking at your own camera under the conditions of the calibration. It is not a universal measurement of eye contact for other cameras or people.
Step 3: Calibrate the sample-answer reader
After the lens reference succeeds, choose 2 · Calibrate reader. Look at the sample answer displayed near the top of the application while calibration runs. This second reference lets the test compare your reading direction with your camera reference. If the two directions are almost identical, the reader may already sit close to your camera; the software can indicate that the test will be less sensitive. That is useful feedback about positioning, not a problem that necessarily needs correcting. If you change your webcam height, screen position or posture substantially, repeat both calibration steps before interpreting a new result.
Step 4: Run the 20-second rehearsal
Once both references are ready, choose 3 · Run 20-second test. Look between the webcam and sample answer as you would during a normal practice response. The program samples usable tracking observations and classifies their approximate direction relative to your lens calibration. It excludes moments it cannot reliably track, such as certain blinks, strong head movement or obscured eyes. If the environment makes tracking unreliable, improve it and try another brief test. When the countdown finishes, the tool displays a result and keeps the camera preview available until you explicitly choose Stop camera.
How to read alignment and tracking coverage
The displayed alignment percentage describes the portion of successfully tracked moments classified as close to the calibrated lens direction. Tracking coverage describes how many of the sampled moments contained usable tracking information. These two numbers answer different questions: a high alignment estimate with low coverage may not be very informative, and a high coverage value does not automatically mean you looked toward the camera. The classification depends on calibration and approximate iris geometry, not on a clinical eye tracker or an independent assessment by a human observer. Do not present the percentage as a verified eye-contact score or a prediction of interview success.
Privacy, permissions and troubleshooting
The existing desktop implementation processes iris landmarks locally and does not save camera frames or gaze measurements when the session is stopped. If a verified model file must be downloaded, that network action obtains the tracking component—not your camera video. To stop the session, use Stop camera; the app releases the video tracks and clears its calibration state. If access fails, check Windows Settings → Privacy & security → Camera and confirm permission for the app. If the model cannot detect your face consistently, check lighting, reflections and camera positioning. Use the tool only if it is comfortable and accessible for you.
Use the result as optional coaching, not a rule
Looking away can be a normal part of listening, recalling a detail, examining shared content or taking a moment to think. Visual gaze direction is not a dependable measure of attention, truthfulness or capability. The most useful outcome of a rehearsal is understanding your setup: can you comfortably read a short prompt, respond in your own words and return attention to the conversation? Try moving the reader a little closer to the webcam and repeating the same practice question. Evaluate clarity and natural delivery as well as your comfort. Never force prolonged eye contact simply to improve an app estimate.
A practical example
Suppose you open Settings → Gaze tester before a mock interview. You calibrate the lens, then the sample answer, and run a 20-second test. The report shows that about 65% of successfully tracked moments aligned with the lens reference, while tracking coverage was about 88%. Those are illustrative numbers, not a score you should target. You move your reader slightly higher, repeat calibration and the test, and ask a practice partner whether your explanation feels more natural. You use the result to understand screen placement rather than claiming the webcam has verified eye contact.
Try this today
Before a practice call, place your webcam at a comfortable height and open Gaze Tester. Complete the two calibration steps and one 20-second run. Write down the alignment estimate and tracking coverage without treating them as performance grades. Move the reader by a small amount, repeat the calibrations and test, and note any differences. Then deliver a ninety-second answer to a familiar question during a mock call. Compare your comfort and communication clarity with feedback from a partner. Prefer the setup that helps you listen and speak naturally.
Before you move on
- Open Settings → Gaze tester → Start camera preview and permit camera access only if you choose to.
- Calibrate the webcam lens before the sample-answer reader.
- Run the optional 20-second test and read both alignment and tracking coverage.
- Treat all gaze estimates as approximate, not verified eye contact or attention.
- Select Stop camera when finished and keep the setup that feels comfortable.
Real questions. Answers built around you.
Gaze Tester is part of the Windows application's preparation tools. Use it for a short rehearsal, then return to QSourceAI's interview practice to develop accurate first-person answers grounded in your own experience. Its readings are positioning aids rather than validated performance metrics.